The EGEG-2D6 intelligence double leads the stomach and intestines electrograph meter |
EGEG series stomach and intestines electrograph meter principle:
The stomach electrograph (Electrogasfrogram, EGG) is uses the superficial electrode from the human body abdominal wall body surface recording stomach electricity activity, takes the stomach function activity the objective electro biology target. May make the reference diagnosis according to the stomach electrograph parameter change to the gastric disease patient, also may to treat makes the appraisal with the medicine effect.
EGEG series stomach and intestines electrograph meter characteristic :
1 Does not have the damage, does not have the pain, the duplication is strong, does not have the taboo sickness, especially by the old age, is physically weak, situation and so on in young child, gastric hemorrhage, shock, inspected for the stomach and intestines disease has provided the convenient condition.
2 The structure simple, the contour exquisite, the performance stable, the operation is simple, is advantageous for carries.
EGEG series stomach and intestines electrograph meter function.
Stomach and intestines electrical signal gathering, memory, processing, profile analysis computation, spectral analysis, expert system, report printing and so on. The EGEG series stomach electrograph meter widely is suitable by its fine quality for each kind of hospital, the teaching and the scientific research department uses, simultaneously also receives the drugs sale profession the welcome.
EGEG series stomach and intestines electrograph meter application scope
Except for the gastric ulcer, the gastritis and the stomach cancer and so on the nature pathological change patient provides outside the reference diagnosis, to the stomach function disease diagnosis, the stomach electrograph also can provide the more reliable scientific basis, this is X barium meal and the gastroscope inspecting office is inferior to. If in the mirror or X and so on the morphology inspection have not seen the obvious pathology change, the patient also has many gastric disease symptoms. The stomach and intestines electrograph inspection is the discovery has the signature, but accurately diagnoses the stomach parasis FD, the stomach rhythm disorder synthesis drafts. (GDS) or the intestinal tract easy violent syndrome (IBS), the stomach to move, the stomach too fast has moved and so on slow. In addition, the stomach electrograph also may for the medicine, the acupuncture and moxibustion, the massage curative effect provide the objective target, also has the certain prospects for development to the stomach cancer early diagnosis and the general survey.
The EGEG series leads the intelligent stomach and intestines electrograph meter related certificate
:
11 analyses parameters and the Chinese digestion academic society stomach and intestines electricity clinical diagnosis standard connects rails, is domestic only conforms to the Chinese digestion academic society stomach and intestines electricity clinical diagnosis standard stomach and intestines power instrumentation. Attains the Anhui Province medical instrument production permit and product certificate of registration . Production permit number: The Anhui medicine tube weapon permits 20.010051 million, the product certificate of registration number: Anhui medicine tube weapon () character 2580008th. Stomach and intestines electrograph meter has the honor to receive two item of newest national monopolies, the patent number: ZL 00219931.9 ZL 01217618.4
Healthy person and common stomach and intestinesd isease patient's stomach and intestines electrograph performance :
1 1. After the healthy adult empty stomach and meal stomach electrograph this compares the rule, the frequency about 3cpm; When empty stomach the stomach electrograph peak-to-peak value in the 130~250 mu V scope, after meal obviously elevates to 250~430uV. After meal the stomach electrograph peak-to-peak value elevates with eats food food nature and the quantity concerns. The stomach electrograph parameter grows along with the age advances, also advances the process along with the age which but reweakens also.
Chinese medicine taste illness patient's stomach and intestines electrograph performance :
Motherland medicine "taste" is primarily involves other systems by the digesting system the function concept. Many researchers take the stomach and intestines electrograph as reflected the stomach and intestines movement the function target, has conducted the substantive research. Thought the different card taste patient has the corresponding stomach and intestines electrograph to be unusual. Actual situation: The real diagnosis liver and stomach disagreement patient's stomach and intestines electrical parameter is high; The actual situation jumbled is next, the empty card is lower than the average man. Cold and heat: The stomach solid hot patient wave amplitude is higher; The taste empty cold namely remarkably reduces. Vitality: The stagnation of flow of vital energy profile is irregular; Blood stasis its frequency is unusual. Also tends to after the Chinese medicine treatment future trouble original unusual stomach and intestines electrograph normally. Therefore the stomach and intestines electrograph may do one kind of objective target assistance dialectical minute, after and uses to judge the treatment the stomach and intestines movement function improvement situation.
Stomach and intestines electrograph in acupuncture and moxibustion, acupuncture and moxibustion research and other aspects applications Many scholars take the stomach and intestines electricity as the target, the observation acupuncture and moxibustion, acupuncture anesthesia the gastro-intestinal tract effect, and discusses its function mechanism. These work has provided many valuable smart materials for the acupuncture and moxibustion channels and collaterals theory essence research and the application。
1. The acupuncture and moxibustion, acupuncture anesthesia and acupuncture point Shi Ci to the stomach and intestines electricity influence, has mainly expounded: The acupuncture and moxibustion has the bidirectional control action, the acupuncture point has the relative specificity, the acupuncture brings about the desired sensation when can obtain the obvious regulating action, the acupuncture effect with stimulates the way and the intensity related, the acupuncture is different to the quick slow wave function, acupuncture anesthesia has the promotion stomach and intestines movement to the stomach and intestines function the restoration function 。
2. The acupuncture influence stomach and intestines function action mechanism research, mainly in the vagus nerve dorsal nucleus , center the seam nucleus and its the neighbor structure, the low position medulla oblongata back and the endogene opium type matter function, the tail nucleus and under the cerebral ganglion different region and so on, thought the above main center structure participated in the acupuncture adjustment stomach and intestines function function 。
Moreover, the stomach and intestines electrograph also may apply to other domains. If for corona moving sickness and astronautics, the aviation medicine stomach and intestines function research keenly found one kind but must to invade the human nature objective target. Also like when the emission medical research, systematically to the ionisation radiation, after the large dose beam illumination, anxiously increased radiation sickness the stomach and intestines function change and machine buries the nature to carry on the discussion.
|
Hefei China branch electronic technology research institute specialized production: Stomach electrograph meter, stomach electrograph, stomach and intestines electrograph meter, stomach and intestines electrograph, stomach and intestines power instrumentation, stomach power instrumentation, EGEG, EGG, stomach electrograph meter, stomach electrograph, stomach and intestines electrograph meter, stomach and intestines electrograph, stomach and intestines power instrumentation, stomach power instrumentation, EGEG, EGG, stomach electrograph meter, stomach electrograph, stomach and intestines electrograph meter, stomach and intestines electrograph, stomach and intestines power instrumentation, stomach power instrumentation, EGEG, EGG, stomach electrograph meter, stomach electrograph, stomach and intestines electrograph meter, stomach and intestines electrograph, stomach and intestines power instrumentation, stomach power instrumentation, EGEG, EGG, stomach electrograph meter, stomach electrograph, stomach and intestines electrograph meter, stomach and intestines electrograph, Stomach and intestines power instrumentation, stomach power instrumentation, EGEG, product and so on EGG. |